<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-29 13-38-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 21 kHz 8953 0,3127
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,8 dBr 3,74 dBr 5,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 21 kHz MIN: 16 kHz % above 76 kHz: 0,3127 Acquired: 2025/06/29 13.37.19 Total samples: 8953 Equivalent time: 0:07:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 5,5 dBr MIN: 1,8 dBr AVE: 3,74 dBr % above 12,2 dBr: 0,0 Last value: 4,0 dBr (2025/06/29 13.37.18) 13.24 13.26 13.28 13.30 13.32 13.34 13.36 0 2 4 6 Pm [dBr]